Wisper 805fe Bedienungshandbuch Seite 10

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 17
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 9
- 10 -
Main Controller specifications
Low voltage safeguard 31.5V
Overload current safeguard 14A
Main hub motor specifications
Motor type Hi speed brushless
Rated power Aus Singapore 200W / NZ Europe North America 250W
Rated voltage 36V
Charger Lithium 115 to 230V 24V fan cooled
8 Simple Trouble shooting
Problem Possible reasons Trouble shooting
Top speed too
slow
1. Low battery voltage
2. Damage to motor driveline
1. Recharge battery fully
2. Call service
Power on but
motor not working
1. Battery not connected
2. Fused
3. Motor connection damaged
1. Re install battery
2. Replace fuse
3. Call service
Driving shorter
distance per
recharge
1. Tyre pressure too low
2. Undercharge or charger fault
3.
Battery capacity loss or
damage
1. Check pressures
2. Recharge completely or
have charger inspected
3. Replace battery
Seitenansicht 9
1 2 ... 5 6 7 8 9 10 11 12 13 14 15 16 17

Kommentare zu diesen Handbüchern

Keine Kommentare